<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-26 23-06-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 43 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 70 kHz 10018 5,9593
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,1 dBr 5,34 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 70 kHz MIN: 13 kHz % above 76 kHz: 5,9593 Acquired: 2026/04/26 23.05.07 Total samples: 10018 Equivalent time: 0:08:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,0 dBr MIN: 4,1 dBr AVE: 5,34 dBr % above 12,2 dBr: 0,0 Last value: 5,9 dBr (2026/04/26 23.05.06) 22.52 22.54 22.56 22.58 23.00 23.02 23.04 0 2 4 6 Pm [dBr]